Does your power plant struggle to keep seals running in ultrapure feed water applications with no real root cause in sight?

 

SITUATION

The failure plaguing many plants for years has been electro-corrosion of the silicon carbide faces within the seal. This is due to electrical charges that build up at the faces along with pure low conductivity reactor grade water being pumped. Electro-corrosion problems that drastically reduced lifetimes of mechanical seals started to occur when Combined Oxygen Treatment (COT or CWT, pH 8…9) was introduced in some existing and in new fossil-fueled power plants (1990s). The water‘s electrical conductivity indicates water purity. As impurities are removed, the feed water becomes an electrical insulator rather than a conductor.

 

APPLICATIONS

  • Large boiler feed pumps: typical pressure up to 580 psi (40 bar), 6.500 rpm, 400 °F (200 °C)
  • Mechanical Seal (M.S.) single, balanced, stationary, spring-type, sliding velocities > 130 ft/s (> 40 m/s), 140 °F (60 °C) in Plan23

 

OUR SOLUTION

EagleBurgmann’s Diamond Face solution is the answer to keeping your seals running. In extensive field installations and laboratory tests, it has been proven that diamond coating is resistant against electrical current and hence resistant to electro corrosion = No SiC chipping and no more dosing systems required. EagleBurgmann Diamond Face seals are installed in power plants across the world and continue to outlast expectations of performing through a few fuel cycles.

 

Display entire case study

 

Diamond face rings after 23,340 hours

Find out more about Diamond Face Technology

 

 

Let us help you!

Our products are used wherever safety and reliability count: in the industries of oil & gas, refineries, petrochemicals, chemicals, pharmaceuticals, food, power, water and many more. About 6,000 employees contribute their ideas, solutions and dedication every day to ensure that customers around the globe can rely on our seals. With our modular TotalSealCare Service, we emphasize our strong customer orientation and offer custom-tailored services for every need. Rely on excellence.

 

 

Contact

EagleBurgmann Industries LP

10035 Brookriver Drive, Houston, TX 77040

Jeff Wonser
District Manager

Phone +1 513-313-1747
Fax +1 713 939 9091
E-Mail: jeff.wonser@eagleburgmann.com

 

 

 

Newsletter

Excellence in Practice

With our free e-mail newsletter „Excellence in Practice“, you will receive first-hand information about current products, services, references and worthwhile industry insights.